The Schedule is shown in a number of tables spread across several pages listed in alphabetical order by parameter, Scroll down this page to find the parameter of interest.

Calibration Capabilities

Gulf Equipment Metrology services (GEMS)

PO Box 10166

Jubail Industrial City, Saudi Arabia  31961

Kevin Sterling        Phone:  966 3 341 9451

CALIBRATION

 

Valid To:  January 31, 2013                                                                      Certificate Number: 3097.01 (Original Certificate can be downloaded at http://www.a2la.org/dirsearchnew/newsearch.cfm or from the home page)

 

In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations1:

I.                   Acoustical

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Sound Level Calibrators

 

94 dB, 104 dB and 114 dB

 

 

0.6 dB

 

B&K Model 4226 and Quest Model 2700

 

 

Acoustical Levels

Sound Level Meters, Noise Dosimeters –

 

94 dB, 104 dB and 114 dB

 

 

 

 

 

31.5 Hz to 4 kHz, Octave Step

 

8 kHz 

 

12.5 kHz to 16 kHz 

 

 

 

 

 

0.4 dB

 

0.5 dB

 

0.7 dB

 

 

 

 

 

B&K Model 4226 Multifunction Acoustic Calibrator

 II.                 Dimensional 

 

Parameter/Equipment

 

 

Range

 

CMC2, 3 (±)

 

 

Comments

 

Angle – Measure

 

1 to 90 Degrees

 

2 arc minutes

 

Sine bar, gage blocks and comparator

 

 

Angle – Measuring Equipment

 

1 to 90 Degrees

 

2 arc minutes

 

Mitutoyo Model 981-101 and 981-203 with sine bar and gage blocks

 

 

Length – Measure

 

 

 

 

(0 to 4) in

 

 

 

(0 to 40) m

 

(2 + 0.5L) μin

 

 

 

1.64  μm/m

 

Pratt & Whitney Measuring System – LabMaster

 

Agilent Model 5530 Laser Measuring System

 

 

Length – Measuring Equipment

 

Up to 84 in

 

 

 

6.8 μin/in

 

Gage blocks

 

 

Surface Flatness

 

 

 

Up to 50 ft

 

 

0.2 % of rdg

 

 

 

Agilent Model 5530 Laser Measuring System

 

 

Diameter – Measure

 

Inside, Outside Class X Master Rings, Plugs & Discs

 

 

 

 

0.05 to 12”

(1.5 mm to 305 mm)

 

 

 

33 ΅in

 

 

 

 

 

Federal  Model 136B-5 Comparator

 III.              Electrical – DC/Low Frequency 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

DC Voltage – Measure

 

Up to 200 mV

200 mV to 2 V

(2 to 20) V

(20 to 200) V

(200 to 1000) V

 

10 V

 

 

5.28 μV/V + 0.1 uV

3.56 μV/V + 0.4 uV

3.94 μV/V + 8 uV

5.30 μV/V + 0.08 mV

5.62 μV/V + 1 mV

 

0.46 μV/V

 

 

Fluke 8508A

 

 

 

 

 

Fluke732B with HP 3458A DMM and Dataproof Scanner

 

 

DC  Voltage – Generate

 

(0 to 220) mV

(0.22 to 2.2) V

(2.2 to 11) V

(11 to 22) V

(22 to 220) V

(220 to 1100) V

 

10 V

 

 

8.71 μV/V + 0.4 uV

5.48 μV/V + 0.7 uV

3.53 μV/V + 2.5 uV

3.51 μV / + 4 uV

9.33 μV/V + 40 uV

6.54 μV/V + 400 uV

 

0.46 μV/V

 

 

Fluke 5700A/EP with 5725A

 

 

 

 

 

Fluke732B

 

DC High Voltage –  Measure

 

(0 to 200) kV

 

 

0.2 % of reading

 

 

Ross Engineering Model  VMP300-5Y with HP 3458A DMM

 

 

DC Current – Generate

 

220 μA

2.2 mA

22 mA

220 mA

2.2 A

11 A

 

Up to 100 A

 

 

40 uA/A + 6 nA

44 uA/A + 7 nA

35.3 uA/A + 40 nA

45.4 uA/A + 0.7 uA

140.6 uA/A + 12 uA

378 uA/A + 480 uA

 

600 uA/A

 

 

 

Fluke 5700A /EP with 5725A

 

 

 

 

 

Fluke 5500A with Valhalla 2555A

 

DC Current Generate & Measure –

 

Clamp-On Ammeters (Toroidal)

 

(Non-Toroidal)

 

 

 

 

(20 to 150) A

(150 to 1000) A

 

(20 to 150) A

(150 to 1000) A

 

 

 

 

0.28% of rdg + 0.015 A

0.29% of rdg + 0.05 A

 

0.58% of rdg + 0.014 A

0.58% of rdg + 0.5 A

 

 

 

 

Fluke Model 5520A with 5500A Coil

 

 

 

 

 


 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

DC Current - Measure

 

200 μA

2 mA

20 mA

200 mA

2 A

20 A

 

(20 to 2000) A

 

 

14 uA/A

14 uA/A

15 uA/A

40 uA/A

178 uA/A

400 uA/A

 

0.25% of rdg

 

Fluke 8508A

 

 

 

 

 

 

Fluke 8508A with current shunts

 

 

DC Resistance –Generate (Fixed Points)

 

0.1 Ω

1 Ω

10 Ω

25 Ω

100 Ω

1 kΩ

10 kΩ

100 kΩ

1 MΩ

 

10MΩ – 1 GΩ

1 GΩ

 

0.23 μΩ/Ω

0.04 μΩ/Ω

0.22 μΩ/Ω

0.48 μΩ/Ω

0.49 μΩ/Ω

1.02 μΩ/Ω

0.07 μΩ/Ω

1.1 μΩ/Ω

7.8 μΩ/Ω

 

10 % of value

12.5 μΩ/Ω

 

L&N  4000 & 4200 series standards with oil bath

 

 

 

 

 

 

 

Victoreen Resistors

Fluke  8508A-7000k

 

 

DC Resistance – Measure

 

 

1 mΩ to 100 mΩ

 

 

(0.1 to 1) Ω

(1 to 10) Ω

(10 to 100) Ω

100 Ω to 1 kΩ

(1 to 10) kΩ

(10 to 100) kΩ

100 kΩ to 1 MΩ

(1 to 10) MΩ

 

20MΩ

200 MΩ

2 GΩ

 

20 GΩ

 

 

1.52 μΩ/Ω + 1.0 μΩ/Ω /Ratio

 

0.58 μΩ/Ω

0.12 μΩ/Ω

0.25 μΩ/Ω

0.50 μΩ/Ω

1.1 μΩ/Ω

0.18 μΩ/Ω

0.40 μΩ/Ω

1.2 μΩ/Ω

 

15 μΩ/Ω + 100 Ω

60 μΩ/Ω + 1 kΩ

530 μΩ/Ω + 0.001 GΩ

 

530 μΩ/Ω + 0.001 GΩ

 

 

Guildline 6675A with Model 6623

               

Guildline 6675A with standard resistors and oil bath

 

 

 

 

 

 

Fluke 8508A (Normal Mode)

 

 

Fluke 8508A (High Voltage )

 


 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Voltage – Generate

 

(0 to 2.2) mV

 

 

 

 

 

 

 

 

(2.2 to 22) mV

 

 

 

 

 

 

 

 

(22 to 220) mV

 

 

 

 

 

 

 

 

(0.22 to 2.2) V

 

 

 

 

 

 

 

 

(2.2 to 22) V

 

 

 

 

 

 

 

 

 

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 300) kHz

(300 to 500) kHz

(0.5 to 1) MHz

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 300) kHz

(300 to 500) kHz

(0.5 to 1) MHz

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 300) kHz

(300 to 500) kHz

(0.5 to 1) MHz

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 300) kHz

(300 to 500) kHz

(0.5 to 1) MHz

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 300) kHz

(300 to 500) kHz

(0.5 to 1) MHz

 

 

 

296 μV/V + 4 uV

165 μV/V + 4 uV

141 μV/V + 4 uV

264 μV/V + 4 uV

608 μV/V + 5 uV

1198 μV/V + 10 uV

1514 μV/V + 20 uV

2818 μV/V + 20 uV

 

295 μV/V + 4 uV

165 μV/V + 4 uV

140 μV/V + 4 uV

264 μV/V + 4 uV

608 μV/V + 5 uV

1198 μV/V + 10 uV

1514 μV/V + 20 uV

2818 μV/V + 20 uV

 

257 μV/V + 12 uV

96 μV/V + 7  uV

85 μV/V + 7 uV

208 μV/V + 7 uV

472 μV/V + 17 uV

916 μV/V + 20 uV

1415 μV/V + 25 uV

2716 μV/V + 45 uV

 

243 μV/V  + 40 uV

93 μV/V  + 15 uV

46 μV/V + 8 uV

78 μV/V + 10 uV

114 μV/V  + 300 uV

435 μV/V + 80 uV

1007 μV/V + 200 uV

1705 μV/V +300 uV

 

244 μV/V + 400 uV

93 μV/V + 150 uV

51  μV/V + 50 uV

78 μV/V +100 uV

104 μV/V + 200 uV

300 μV/V + 600 uV

1008 μV/V + 2 mV

1505 μV/V + 3.2 mV

 

 

 

Fluke  5700A/EP

 

 

 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Voltage – Generate (cont)

(22 to 220) V

 

 

 

 

 

 

 

 

(220 to 1100) V

 

 

 

(229 to 750) V

 

 

 

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 300) kHz

(300 to 500) kHz

(0.5 to 1) MHz

 

(0.04 to 1) kHz

(1 to 20) kHz

(20 to 30) kHz

 

(30 to 50) kHz

(50 to 100) kHz

 

 

 

 

289 μV/V + 4 mV

94 μV/V + 1.5 mV

57 μV/V + 0.6 mV

95 μV/V + 1 mV

162 μV/V + 2.5 mV

900 μV/V + 16 mV

4400 μV/V + 40 mV

800 μV/V + 80 mV

 

90 μV/V + 2 mV

115 μV/V + 6 mV

600 μV/V + 11 mV

 

600 μV/V + 11 mV

2300 μV/V + 45 mV

 

 

 

 

 

Fluke  5700A/EP

 

 

 

 

 

 

 

 

Fluke  5700A/EP with 5725A

 

AC Voltage – Measure

AC-DC Difference

 

0.006 V

 

 

 

 

 

 

 

 

 

 

 

 

 

0.01 V

 

 

 

 

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

 

 

 

 

800 μV/V

600 μV/V

600 μV/V

600 μV/V

600 μV/V

600 μV/V

600 μV/V

800 μV/V

1200 μV/V

2000 μV/V

2400 μV/V

2400 μV/V

2400 μV/V

 

500 μV/V

500 μV/V

500 μV/V

500 μV/V

500 μV/V

500 μV/V

500 μV/V
500 μV/V

700 μV/V

1000 μV/V

1600 μV/V

1800 μV/V

1800 μV/V

 

 

 

 

Fluke Model 792A AC/DC Transfer Standard


 

 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Voltage – Measure

AC-DC Difference (cont)

 

0.02 V

 

 

 

 

 

 

 

 

 

 

 

 

 

0.06 V

 

 

 

 

 

 

 

 

 

 

 

 

 

0.10 V

 

 

 

 

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

 

 

 

 

 

300 μV/V

240 μV/V

200 μV/V

200 μV/V

200 μV/V

200 μV/V

200 μV/V

300 μV/V

600 μV/V

1000 μV/V

1200 μV/V

1400 μV/V

1400 μV/V

 

300  μV/V

200 μV/V

140 μV/V

100 μV/V

100 μV/V

100 μV/V

100 μV/V

300 μV/V

360 μV/V

1000 μV/V

1200 μV/V

1400 μV/V

1400 μV/V

 

200 μV/V

160 μV/V

90 μV/V

90 μV/V

90 μV/V

90 μV/V

90 μV/V

110 μV/V

200 μV/V

380 μV/V

500 μV/ V

600 μV/V

600 μV/V

 

 

 

 

 

Fluke Model 792A AC/DC Transfer Standard


 

 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Voltage – Measure

AC-DC Difference (cont)

 

0.20 V

 

 

 

 

 

 

 

 

 

 

 

 

 

0.60 V

 

 

 

 

 

 

 

 

 

 

 

 

 

1.00 V

 

 

 

 

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

 

 

 

 

 

160 μV/V

120 μV/V

80 μV/V

80 μV/V

80 μV/V

80 μV/V

80 μV/V

100 μV/V

200 μV/V

320 μV/V

400 μV/V

520 μV/V

520 μV/V

 

160 μV/V

140 μV/V

50 μV/V

36 μV/V

36 μV/V

36 μV/V

36 μV/V

60 μV/V

90 μV/V

200 μV/V

220 μV/V

240 μV/V

240 μV/V

 

240 μV/V

100 μV/V

44 μV/V

24 μV/V

24 μV/V

24 μV/V

24 μV/V

50 μV/V

60 μV/V

200 μV/V

210 μV/V

220 μV/V

220 μV/V

 

 

 

 

 

Fluke Model 792A AC/DC Transfer Standard


 

 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Voltage – Measure

AC-DC Difference (cont)

 

2.00 V

 

 

 

 

 

 

 

 

 

 

 

 

 

6.00 V

 

 

 

 

 

 

 

 

 

 

 

 

 

10.00 V

 

 

 

 

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

 

 

 

 

 

240 μV/V

70 μV/V

40 μV/V

16 μV/V

16 μV/V

16 μV/V

16 μV/V

40 μV/V

50 μV/V

200 μV/V

210 μV/V

220 μV/V

220 μV/V

 

240 μV/V

80 μV/V

40 μV/V

18 μV/V

18 μV/V

18 μV/V

18 μV/V

50 μV/V

60 μV/V

200 μV/V

210 μV/V

220 μV/V

220 μV/V

 

240 μV/V

90 μV/V

50 μV/V

24 μV/V

24 μV/V

24 μV/V

24 μV/V

40 μV/V

50 μV/V

200 μV/V

210 μV/V

220 μV/V

220 μV/V

 

 

 

 

 

Fluke Model 792A AC/DC Transfer Standard


 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Voltage – Measure

AC-DC Difference (cont)

 

20.00 V

 

 

 

 

 

 

 

 

 

 

 

 

 

60.00 V

 

 

 

 

 

 

 

 

 

100.00 V

 

 

 

 

 

 

 

 

200.0 V

 

 

 

 

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

300 kHz

500 kHz

800 kHz

1 MHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

100 kHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

 

 

 

 

 

 

240 μV/V

80 μV/V

44 μV/V

24 μV/V

24 μV/V

24 μV/V

24 μV/V

40 μV/V

50 μV/V

110 μV/V

220 μV/V

230 μV/V

230 μV/V

 

240 μV/V

80 μV/V

30 μV/V

30 μV/V

30 μV/V

30 μV/V

80 μV/V

90 μV/V

200 μV/V

 

280 μV/V

100 μV/V

50 μV/V

40 μV/V

40 μV/V

40 μV/V

90 μV/V

100 μV/V

 

280 μV/V

100 μV/V

50 μV/V

40 μV/V

40 μV/V

40 μV/V

90 μV/V

100 μV/V

 

 

 

 

 

 

Fluke Model 792A AC/DC Transfer Standard


 

 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Voltage – Measure

AC-DC Difference (cont)

 

600.0 V

 

 

 

 

 

 

 

 

1000 V

 

 

 

 

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

 

10 Hz

20 Hz

40 Hz

100 Hz

1 kHz

10 kHz

20 kHz

50 kHz

 

 

 

 

 

360 μV/V

120 μV/V

60 μV/V

46 μV/V

40 μV/V

40 μV/V

90 μV/V

110 μV/V

 

380 μV/V

90 μV/V

46 μV/V

46 μV/V

44 μV/V

44 μV/V

90 μV/V

120 μV/V

 

 

 

 

 

 

Fluke Model 792A AC/DC Transfer Standard

 

AC High Voltage – Measure @ 60 Hz

 

(0 to 75) kV

 

 

4 % of rdg

 

 

Ross Engineering VMP300-5Y with HP 3458A DMM

 

 

AC Current – Generate

 

(0  to 220) uA

 

 

 

 

 

(0.22 to 2.2) mA

 

 

 

 

 

(2.2 to 22) mA

 

 

 

 

 

 

 

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 1) kHz

(1 to 5) kHz

(5 to 10) kHz

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 1) kHz

(1 to 5) kHz

(5 to 10) kHz

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 1) kHz

(1 to 5) kHz

(5 to 10) kHz

 

 

 

261 μV/V + 16 nA

166 μV/V+ 10 nA

129 μV/V+ 8 nA

284 μV/V + 12 nA

1101 μV/V + 65 nA

 

287 μV/V + 40 nA

199  μV/V + 35 nA

171 μV/V + 35 nA

234 μV/V + 110 nA

1107 μV/V + 650 μA

 

287 μV/V + 400 nA

199 μV/V + 350 nA

170 μV/V + 350 nA

234 μV/V + 550 nA

1107 μV/V + 5000 nA

 

 

 

 

Fluke  5700A/EP with 5725A

 


 

 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Current –Generate

(continued)

 

(22 to 220) mA

 

 

 

 

 

(0.22 to 2.2) A

 

 

 

(2.2 to 11) A

 

 

 

(11 to 20) A

 

 

 

 

(10 to 20) Hz

(20 to 40) Hz

(0.04 to 1) kHz

(1 to 5) kHz

(5 to 10) kHz

 

(0.02 to 1) kHz

(1 to 5) kHz

(5 to 10) kHz

 

(0.04 to 1) kHz

(1 to 5) kHz

(5 to 10) kHz

 

(45 to 100) Hz

(0.1 to 1) kHz

(1 to 5) kHz

 

 

 

 

261 μV/V + 4 μA

3.5 μV/V + 3.5 μA

129 μV/V + 3.5 μA

266  μV/V + 3.5 μA

1107 μV/V + 10 μA

 

266 μV/V + 35 μA

452 μV/V + 80 μA

7000 μV/V + 160 μA

 

477 μV/V + 170 μA

961 μV/V + 380 μA

3601 μV/V + 750 uA

 

0.12 % of rdg + 5 mA

0.15 % of rdg + 5 mA

3 % of rdg + 5 mA

 

 

 

 

 

Fluke  5700A/EP

 

AC Current –Generate/Measure

 

Toroidal, Type Clamps

(10 to 1025) A

 

“Other type” of Clamps

(10 to 1025) A

 

 

 

 

 

(45 to 65) Hz

(65 to 440) Hz

 

(45 to 65) Hz

(65 to 440) Hz

 

 

 

 

3 % of rdg + 0.09A

3.1 % of rdg + 0.025A

 

3.1 % of rdg + 0.9 A

3.2 % of rdg + 0.25 A

 

 

 

 

 

Fluke Model 5500A/coil with 5520A

 

AC Current – Measure

 

Up to 200 μA

 

 

 

200 μA to 2 mA

 

 

 

(2 to 20) mA

 

 

 

 

10 Hz to 10 kHz

(10 to 30) kHz

(30 to 100) kHz

 

10 Hz to 10 kHz

(10 to 30) kHz

(30 to 100) kHz

 

10 Hz to 10 kHz

(10 to 30) kHz

(30 to 100) kHz

 

 

 

315 μV/V + 0.02 μA

678 μV/V + 0.02 μA

4004 μV/V + 0.02 μA

 

296 μV/V + 0.0002 mA

674 μV/V + 0.0002 mA

4016 μV/V + 0.002 mA

 

298 μV/V + 0.002 mA

666 μV/V + 0.002 mA

4016 μV/V + 0.002 mA

 

 

 

 

Fluke Model 8508A

 


 

 

 

Parameter/Range

 

 

Frequency

 

CMC2 (±)

 

 

Comments

 

AC Current – Measure

(cont)

 

(20 to 200) mA

 

 

200 mA to 2 A

 

 

 

(2 to 20) A

 

 

 

 

10 Hz to 10 kHz

(10 to 30) kHz

 

10 Hz to 2 kHz

(2 to 10) kHz

10 to 30) kHz

 

10 Hz to 2 kHz

(2 to 10) kHz

 

 

 

 

269 μV/V + 0.02 mA

607 μV/V + 0.02 mA

 

617 μV/V + 0.2 mA

748 μV/V + 0.2 mA

3 % of rdg  + 0.2 mA

 

820 μV/V + 0.002 A

2.5 % of rdg + 0.002 A

 

 

 

 

 

Fluke Model 8508A

 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Capacitance – Measure

 

1 KHz

 

 

 

120 (100) Hz, 10 KHz

 

 

 

 

(5 to 1000) pf

 

 

 

1 nf to 10 mF

 

 

 

 

5.13 parts in 106

 

 

 

1.2 % of rdg

 

 

 

Andeen  Hagerling Model 2500A Capacitance Bridge

 

HP Model 4262A

 

Capacitance – Generate

 

1000 Hz

 

 

1 kHz

 

 

 

 

 

 

 

 

 

10 kHz

 

 

 

100 pf

 

 

2 pf

100 pf

1000 pf

1800 pf

10 nF

100 nF

1 μF

10 μF

1000 μF

 

1 pf

10 pF

19 pF

100 pf

1000 pf

10 nF

 

 

 

 

2.6  μf/F

 

 

9000 μF/F

300 μF/F

300 uF/F

300 μF/F

200 μF/F

200 μF/F

200 μF/F

200 μF/F

8000 μF/F

 

9000 μF/F

600 μF/F

9400 μF/F

200 μF/F

400 μF/F

300 μF/F

 

 

 

 

Andeen Hagerling Model  AH11A

 

HP DUT Box Model 16361A

 

 

 

 

 

 

 

 

HP DUT Box Model 16362A

 

 


 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Capacitance  - Generate

(cont)

 

10 kHz

 

 

 

 

@ 1 kHz

 

 

 

 

100 nF

1000 nF

10 μF

100 μF

 

(0.19 to 0.3999) nF

(0.4 to 1.0999) nF

(1.1 to 3.2999) nF

(3.3 to 10.9999) nF

(11 to 32.999) nF

(33 to 109.999) nF

(110 to 329.999) nF

(0.33 μF to 1.09999 μF

(1.1 to 3.299999) μF

(3.3 to 10.9999) μF

(11 to 32.9999) μF

(33 to 109.9999) μF

(110  to 329.999) μF

(0.33 to 1.09999) mF

(1.1 to 3.2999) mF

(3.3 to 10.9999) mF

(11 to 32.9999) mF

(33 to 110) mF

 

 

 

 

300 μF/F

400 μF/F

4000 μF/F

5000 μF/F

 

0.6 % of rdg + 0.01 nF

0.5 % of rdg + 0.01 nF

0.5 % of rdg + 0.01 nF

0.25 % of rdg + 0.01nF

0.25 % of rdg + 0.1 nF

0.32 % of rdg + 0.1 nF

0.28 % of rdg + 0.3 nF

0.4 6 % of rdg + 1 nF

0.25 % of rdg + 3 nF

0.33 % of rdg  + 10 nF

0.40 % of rdg + 30 nF

0.64 % of rdg + 100 nF

0.45 % of rdg + 300 nF

0.45 % of rdg + 1 μF

0.45 % of rdg + 3 μF

0.45 % of rdg +10 μF

0.75 % of rdg + 30 μF

1.1 % of rdg + 100 μF

 

 

 

 

 

HP DUT Box Model 16362A

 

 

 

Fluke  5520A

 

 

Parameter/Range

 

 

Frequency

 

 

CMC2 (±)

 

 

Comments

 

Inductance – Generate

(Fixed Point)

 

10 mH, 1 kHz

100 mH, 1 kHz

100 μH, 1 kHz

 

0.01 mH

0.5 mH

0.36 μH

 

 

GR Model 1482-B, 1482-H, 1482-L

 

Inductance – Measure

 

0.01 μHz to 1999 Hz

 

0.3 % of reading

 

HP Model 4262A Digital LCR Meter

 


 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Electrical Calibration of Thermocouple Devices

 

Type B

 

 

 

 

 

Type C

 

 

 

Type E

 

 

 

 

 

Type J

 

 

 

 

 

Type K

 

 

 

 

 

Type L

 

 

 

Type N

 

 

 

 

 

Type R

 

 

 

 

 

 

(600 to 800) °C

(800 to 1000) °C

(1000 to 1550) °C

(1550 to 1820) °C

 

(0 to 150) °C

(150 to 650) °C

(650 to 1000) °C

(1000 to 1800) °C

 

(-250 to -100) °C

(-100 to -25) °C

(-25 to 250) °C

(350 to 650) °C

(650 to 1000) °C

 

(-210 to -100) °C

(-100 to -30) °C

(-30 to 150) °C

(150 to 760) °C

(760 to 1200) °C

 

(-200 to -100) °C

(-100 to -25) °C

(-25 to 120) °C

(120 to 1000) °C

(1000 to 1372) °C

 

(-200 to -100) °C

(-100 to 800) °C

(800 to 900) °C

 

(-200 to -100) °C

(-100 to -25) °C

(-25 to 120) °C

(120 to 410) °C

(410 to 1300) °C

 

(0 to 250) °C

(250 to 400) °C

(400 to 1000) °C

(1000 to 1767) °C

 

 

 

 

 

0.44 °C

0.34 °C

0.30 °C

0.33 °C

 

0.30 °C

0.26 °C

0.31 °C

0.50 °C

 

0.50 °C

0.16 °C

0.14 °C

0.16 °C

0.21 °C

 

0.27 °C

0.16 °C

0.14 °C

0.17 °C

0.23 °C

 

0.33 °C

0.18 °C

0.16 °C

0.26 °C

0.40 °C

 

0.37 °C

0.26 °C

0.17 °C

 

0.40 °C

0.22 °C

0.19 °C

0.18 °C

0.27 °C

 

0.57 °C

0.35 °C

0.33 °C

0.40 °C

 

 

 

 

 

Fluke  5520A

 

 

 

 

 

 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Electrical Calibration of Thermocouple Devices

(cont)

 

Type S

 

 

 

 

Type T

 

 

 

 

Type U

 

 

 

 

 

 

(0 to 250) °C

(250 to 400) °C

(400 to 1000) °C

(1000 to 1767) °C

 

(-250 to -150) °C

(-150 to 0) °C

(0 to 120) °C

(120 to 400) °C

 

(-200 to 0) °C

(0 to 600) °C

 

 

 

 

 

0.57 °C

0.35 °C

0.33 °C

0.40 °C

 

0.63 °C

0.24 °C

0.16 °C

0.14 °C

 

0.56 °C

0.27 °C

 

 

 

 

 

Fluke  5520A

 

 IV.      Electrical/RF/Microwave

 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

RF Absolute Power –Measure

 

Power Reference 1mW, Type N (f), 50 Ω, 50 MHz

 

(-30to + 20) dBm

(100 kHz  to 2 GHz) 75 Ω

 

(-30 to + 20) dBm

(100 kHz  to 4.2 GHz) 50 Ω

 

(-30 to + 20) dBm

(50 MHz  to 26.5) 50 Ω

 

(-70 to + 20) dBm

(50 MHz  to 26.5) 50 Ω

 

 

9 μW

 

 

4.4% of  rdg

VSWR: ≤ 1.2:1

 

3.6% of  rdg

VSWR: ≤ 1.6:1

 

3.7% of  rdg

VSWR: ≤ 1.25:1

 

4.4% of  rdg

VSWR: ≤ 1.29:1

 

HP 436A with  HP  8485A Sensor

 

HP 436A with  HP  8483A Sensor

 

HP 436A with  HP  8482A Sensor

 

HP 436A with  HP  8485A Sensor

 

HP 436A with  HP  8485D Sensor

 

 

Tune RF Power

Absolute - Measure

 Relative – Measure

 

100 KHz to 26.5 GHz

(+30 to -130) dBm

50Ω

 

 

0.99 dB

 

Rohde & Schwarz Model FSMR 26


 

 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

RF Absolute Power

Generate

 

(+10 to -135) dBm ≤ 2.5 GHz

 

(+10 to -135) dBm ≤ 3.25 GHz

 

 

1.2 dB

VSWR <2.5:1

 

1.8 dB

VSWR <1.5:1

 

HP 8648C Signal Generator

 V.        Mechanical 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Torque

 

(0 to 2000) lb·ft.

 

(0 to 200) lb·in

 

 

0.12 % of rdg

 

0.12 % of rdg

 

 

AKO Model TSD 2050/3000

 

Acceleration

Sensitivity- Frequency Response

 

(20 to 10 000) Hz

Sensitivity 10 mV/g

 

 

6.4% of rdg

 

Vibration Test Systems with 3120A Accelerometer

 

 

Force

 

Up to 55 000 lbf

 

 

 

0.05 % of reading

 

 

Tovey Engineering Model 55K

  

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Mass – Fixed Points

 

5  kg

2 kg

1 kg

500 g

50 g

20 g

10 g

5 g

2 g

1 g

500 mg

200 mg

100 mg

50 mg

20 mg

10 mg

5 mg

2 mg

1 mg

 

 

5.4 mg

2.4 mg

0.49 mg

0.99 mg

0.29 mg

0.025 mg

0.018 mg

0.016 mg

0.013 mg

0.014 mg

0.0088 mg

0.0064 mg

0.0062 mg

0.0054 mg

0.0050 mg

0.0052 mg

0.0050 mg

0.0050 mg

0.0040 mg

 

 

OIML Class E1

OIML Class E2

OIML Class E1

OIML Class F1 weights and comparators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mass Comparators –

 

 

 

 

 

Digital Scales/ Comparator

 

20 g

200 g

3 kg

10 kg

30 kg

 

100 g

 

50 kg

 

 

2 kg

 

10 kg

 

 

0.0012 mg

0.0056 mg

0.5 mg

3.0 mg

50 mg

 

0.25 mg

 

5 mg

 

 

0.01 mg

 

7.7 mg

 

 

Reverifications Comparators

 

 

 

 

Ainsworth 100A

 

Mettler Toledo XP 64003L

 

Mettler Toledo AX2005

 

Mettler Toledo PR1003

 

 

Pressure – Generate

 

Hydraulic

 

 

 

 

 

Pneumatic

 

 

 

(7.25 to 20 000) psi

 

 

(10 to 16 000) psi

 

 

(2 to 500) psi

 

 

 

0.0051% of rdg

 

 

0.015 % of rdg

 

 

0.008 % of rdg

 

 

 

Ruska Model 2485-930S

 

Pressurements Model M2800-3-S

 

Pressurements Model T3500/3

 

 VI.       Thermodynamics 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Temperature – Measure

 

 

(-195 to 600)  °C

 

 

(601 to 1100) °C

 

 

0.00185 °C

 

 

0.596 °C

 

SPRT and super thermometer

 

Thermocouple and

scanner 1560

 

 

Temperature – Generate (Fixed Points)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple Point of water

660.323 °C

231.928 °C

419.537 °C

-38.7344 °C

-195 °C

 

 

 

 

 

 

(-80 to 500) °C

 

(501 to 600) °C

 

(601 to 1100) °C

 

0.21 mK

3.6 mK

2.6 mK

2.6 mK

2.6 mK

3.1 mK

 

 

 

 

 

 

0.0023 °C

 

0.63 °C

 

0.83 °C

 

TPW Cell

FP Aluminum Cell

FP Tin Cell

FP Zinc Cell

TP Mercury Cell

Liquid Nitrogen Comparison Calibrator Hart Model 7190 Hart 1590 Super Thermometer

Hart SPRT

 

Hart Model 7380

Hart Model 7012

Hart Model 6035

Hart Model 6050

Omega Model LMF 3550

Hart 1590 Super Thermometer

Hart SPRT

 

 

Relative Humidity

 

 

(10 to 95) % RH

 

0.51 % RH

 

Thunder Scientific Model 2500

 

 VII.      Time and Frequency 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Frequency - Measure

 

 

 

10 MHz

 

 

<1.2 X 10-12 Hz

 

Fluke Model 910R GPS   

 


 

 

Parameter/Equipment

 

 

Range

 

CMC2 (±)

 

 

Comments

 

Sinewave Frequency – Measuring Equipment

 

0.1 Hz to 20 MHz

200 Hz to 80 MHz

 

 

10 MHz to 20 GHz

 

 

5.8 μHz/Hz

0.0058 Hz

 

 

0.17 Hz

 

HP 3325A/HP 5345A

HP 3335A Opt. 001/ HS 20/ 54610B/910R

 

HP 83712B/910R

 

Sinewave Frequency – Measure

 

(0 to 400) MHz

(0.4 to 1.6) GHz

(1.5 to 26) GHz

 

8.1 X 10-5 Hz

05.8 Hz

2.4 Hz

 

HP 5345A

HP 5345A/ HP 5355A

HP 5345A/HP 5355A/ HP 5356B

 

 

Time Interval

 

10 nS to 20 000 S

 

 

2.3 nS

 

HP 5345A

 

Stop Watches

 

(0.4 to 24) Hours

 

0.02 % of time Interval

 

 

Fluke 910R  GPS

 

 

____________________________________________

1 This laboratory offers commercial calibration service.

 

2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment.  Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2.  The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.

 

3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.